Point-of-care hemolysis detection in blood gas specimens directly at the emergency department
Hemcheck, Karlstad, Sweden.ORCID iD: 0000-0002-3449-1050
Västmanland Hospital, Västerås, Sweden.
Central Hospital, Karlstad, Sweden.ORCID iD: 0000-0003-4624-3430
2019 (English)In: Scandinavian Journal of Clinical and Laboratory Investigation, ISSN 0036-5513, E-ISSN 1502-7686, Vol. 79, no 5, p. 283-287Article in journal (Refereed) Published
Abstract [en]

 Blood gas analysis represents an important and frequently used clinical decision support. Spurious haemolysis is common at the emergency department (ED) and causes clinically relevant bias to many analyses. Blood gas analysers inability to identify hemolysis can therefore lead to clinical misinterpretations. The objective of this study was to assess the proportion of haemolytic blood gas samples performed at the ED and calculate the predictive values of a novel point-of-care solution for haemolysis detection. Approximately 100 µl of blood from anonymized syringes including venous or arterial blood was, directly after performed blood gas analysis, tested with the POC-Method (Helge H10 s-system, Hemcheck, Karlstad, Sweden) at the ED and result recorded. Thereafter the blood was centrifuged (2000 g) for 10 minutes, 100 µl of plasma put into vials and run in batches of 40 daily on an AU680 analyzer (Beckman Coulter, Brea, California, USA) used as reference method. The threshold for clinically relevant hemolysis was defined as ≥50 mg/dL free haemoglobin. Out of 1270 samples, haemolysis was detected in 7.9% (n = 100). The POC-method identified haemolytic samples with a sensitivity of 80%, specificity of 99%, positive and negative predictive values was 89% and 98% respectively. Spurious hemolysis is frequently present in blood gas samples at the ED and should be taken into consideration when assessed in patients. Errors could be detected directly at the point-of-care with a novel technology for hemolysis detection.

Place, publisher, year, edition, pages
Taylor & Francis, 2019. Vol. 79, no 5, p. 283-287
Keywords [en]
Blood gas analysis, Hemolysis, Emergency Service, Hospital, Point-of-Care Systems
National Category
Clinical Laboratory Medicine
Research subject
Nursing Science
Identifiers
URN: urn:nbn:se:kau:diva-102570DOI: 10.1080/00365513.2019.1612089ISI: 000481824100002PubMedID: 31066302Scopus ID: 2-s2.0-85065531371OAI: oai:DiVA.org:kau-102570DiVA, id: diva2:1923532
Available from: 2024-12-27 Created: 2024-12-27 Last updated: 2025-10-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Duhalde, Henrik

Search in DiVA

By author/editor
Duhalde, HenrikKarlsson, Mathias
In the same journal
Scandinavian Journal of Clinical and Laboratory Investigation
Clinical Laboratory Medicine

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 59 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • apa.csl
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf