Change search
ReferencesLink to record
Permanent link

Direct link
Why ultra high performance liquid chromatography produces more tailing peaks than high performance liquid chromatography, why it does not matter and how it can be addressed
AstraZeneca R&D Lund, SE-221 87 Lund, Sweden.
Karlstad University, Faculty of Technology and Science, Department of Chemistry and Biomedical Sciences.
Department of Physical and Analytical Chemistry, BMC Box 577, SE-751 23 Uppsala, Sweden.
AstraZeneca Nordic Headquarters (ISMO), Södertälje. (, SE-151 85 Sweden)
Show others and affiliations
2011 (English)In: Journal of chromatography. B, ISSN 1570-0232, E-ISSN 1873-376X, Vol. 1218, no 39, 6914-6921 p.Article in journal (Refereed) Published
Abstract [en]

The purpose of this study is to demonstrate, with experiments and with computer simulations based on a firm chromatographic theory, that the wide spread perception of that the United States Pharmacopeia tailing factor must be lower than 2 (Tf < 2) is questionable when using the latest generation of LC equipment. It is shown that highly efficient LC separations like those obtained with sub-2 μm porous and 2.7 μm superficially porous particles (UHPLC) produce significantly higher Tf-values than the corresponding separation based on 3 μm porous particles (HPLC) when the same amount of sample is injected. Still UHPLC separations provide a better resolution to adjacent peaks. Expressions have been derived that describe how the Tf-value changes with particle size or number of theoretical plates. Expressions have also been derived that can be used to scale the injection volume based on particle size or number of theoretical plates to maintain the Tf-value when translating a HPLC separation to the corresponding UHPLC separation. An aspect that has been ignored in previous publications. Finally, data obtained from columns with different age/condition indicate that Tf-values should be complemented by a peak width measure to provide a more objective quality measure.

Place, publisher, year, edition, pages
2011. Vol. 1218, no 39, 6914-6921 p.
Keyword [en]
HPLC, Isotherm, Particle size, Simulation, Translation, UHPLC
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:kau:diva-29017DOI: 10.1016/j.chroma.2011.08.018ISI: 000295241500009OAI: oai:DiVA.org:kau-29017DiVA: diva2:647906
Available from: 2013-09-12 Created: 2013-09-12 Last updated: 2015-12-11Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textFull text

Search in DiVA

By author/editor
Forssén, PatrikFornstedt, Torgny
By organisation
Department of Chemistry and Biomedical Sciences
In the same journal
Journal of chromatography. B
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 38 hits
ReferencesLink to record
Permanent link

Direct link