WKA-1R robot-assisted quantitative assessment of airway management
Show others and affiliations
2008 (English)In: International Journal of Computer Assisted Radiology and Surgery, 3(6): 543-550, ISSN 1861-6410, Vol. 3, no 6, 543-550 p.Article in journal (Refereed) Published
Abstract [en]

Object

The emerging field of medical robotics aims tointroduce intelligent tools for physician support. The main challenges for developing efficient medical robotic training systems are simulating real-world conditions of the task and assuring training effectiveness. High anatomic fidelity has been achieved in current systems, but they are limited to provide merely subjective assessments of the training progress. We simulated airway intubation using a unique medical robot and developed objective performance criteria to assess task performance.

Materials and methods

A patient simulation robot was designed to mimic real-world task conditions and provide objective assessments of training progress. The Waseda– Kyotokagaku Airway No. 1R (WKA-1R) includes a human patient model with embedded sensors. An evaluation function was developed for the WKA-1R to quantitatively assess task performance. The evaluation includes performance indices and coefficient weighting. The performance indices were defined based on experiments carried out with medical doctors and from information found in the medical literature. The performance indices are: intubation time, jaw opening, incisor teeth force, cuff pressure, tongue force and tube position. To determine the weighting of coefficients, we used discriminant analysis.

Results

Experiments were carried out with volunteers to determine the effectiveness of the WKA-1R to quantitatively evaluate their performance while performing airway management. We asked subjects from different levels of expertise (from anesthetists to unskilled) to perform the task. From the experimental results, we determined operator effectiveness using the proposed performance indices. We found a significant difference between the experimental groups by evaluating their performances using the proposed evaluation function (P < 0.05).

Conclusions

The WKA-1R robot was designed to quantitatively acquire information on the performances of trainees during intubation procedures. From the experimental results, we could objectively determine operator effectiveness while providing quantitative task assessments.

Place, publisher, year, edition, pages
Springer, 2008. Vol. 3, no 6, 543-550 p.
National Category
Robotics
Identifiers
URN: urn:nbn:se:kau:diva-25785DOI: 10.1007/s11548-008-0238-1OAI: oai:DiVA.org:kau-25785DiVA: diva2:599566
Available from: 2013-01-22 Created: 2013-01-22 Last updated: 2015-06-10Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Solis, Jorge
By organisation
Department of Physics and Electrical Engineering
Robotics

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 18 hits
ReferencesLink to record
Permanent link

Direct link