Development of an Airway Management Training System that Embeds an Array of Sensors on a Conventional Mannequin
Show others and affiliations
2007 (English)In: Intelligent Robots and Systems, 2007. IROS 2007. IEEE/RSJ International Conference on, 2007, 1296-1301 p.Conference paper, (Refereed)
Abstract [en]

Airway management is provided by emergency medical technicians or anesthetists in order to save unconscious patients who are unable to breathe. Even though it is a basic technique, many accidents may occur when the procedure is not provided followed. In order to avoid any risks to patients, emergency medical technicians are required to practice airway management using training devices such as mannequins; which are designed to accurately reproduce the human anatomy. However, such training devices do not provide any quantitative information about the learning progress of trainees (passive training). For that purpose, we have proposed the development of a airway management training system which is designed to embed array of sensors so that quantitative information of trainees' performance can be acquired. In this paper, we are presenting the Waseda-KyotoKagaku airway No. 1 (WKA-1). The WKA-1 consists of three different kinds of array of sensors which are embedded into a conventional mannequin. In order to embed the array of sensors, we have simplified the design of some of the simulated organs (upper airway, oral cavity, tongue and teeth) of the mannequin. A set of evaluation parameters were proposed based on the information collected through the sensors. A set of experiments were proposed to experimentally verify the effectiveness of the proposed evaluation parameters to quantitatively detect differences among different levels of skills (anesthetists and unskilled persons).

Place, publisher, year, edition, pages
2007. 1296-1301 p.
National Category
Robotics
Identifiers
URN: urn:nbn:se:kau:diva-18297DOI: 10.1109/IROS.2007.4399580ISBN: 978-1-4244-0912-9 (print)ISBN: 978-1-4244-0912-9 (print)OAI: oai:DiVA.org:kau-18297DiVA: diva2:591927
Conference
IROS 2007. IEEE/RSJ International Conference on Intelligent Robots and Systems, Oct. 29 2007-Nov. 2 2007, San Diego, CA
Available from: 2013-01-21 Created: 2013-01-21 Last updated: 2015-06-08Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Solis, Jorge
By organisation
Department of Physics and Electrical Engineering
Robotics

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 15 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf