Determination of specific heat capacity by Transient Plane Source
Chalmers, Sweden.ORCID iD: 0000-0002-4098-402X
Chalmers, Sweden.
Chalmers, Sweden.
2012 (English)In: Proceedings of the 5th International Building Physics Conference, 2012, p. 131-136Conference paper, Published paper (Refereed)
Abstract [en]

The specific heat capacity of a material is of importance for thermal storage. Transient Plane Source (TPS) is a measurement method with a sensor that works both as a heat source and as a resistance thermometer. The standard TPS measurement gives the thermal conductivity and thermal diffusivity of an isotropic material which can be used to calculate the heat capacity. The thermal properties of an anisotropic material can be measured if the heat capacity is known. A method for heat capacity measurement exists, where the TPS sensor is attached to a golden sample container which is surrounded by insulation. However, its results are based on an assumption of negligible heat losses which leads to uncertainties in the results. From that position, this paper aims to give an answer of how to model the heat losses from the specific heat measurements with TPS. A new set-up is introduced, where the sensor with the container hangs freely in a steel tube in order to get more predictable heat losses. The results show that the measurements can be modelled as a network of lumps connected by conductances which can be approximated as constant. Thereby, the conductances out from the system can be solved from a reference measurement and used as input data for a model of a measurement with a sample. The model seems to underestimate the heat capacity, which might be a consequence of temperature dependent effects on the conductances from convection. The tube in the set-up could be evacuated to minimize those losses.

Place, publisher, year, edition, pages
2012. p. 131-136
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:kau:diva-103697OAI: oai:DiVA.org:kau-103697DiVA, id: diva2:1947640
Conference
5th International Building Physics Conference
Available from: 2025-03-26 Created: 2025-03-26 Last updated: 2025-03-26Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records

Berge, Axel

Search in DiVA

By author/editor
Berge, Axel
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 2 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • apa.csl
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf