Effektivisering av värmepumpen på Sjöstad reningsverk
2002 (Swedish)Independent thesis Basic level (professional degree)Student thesis
Abstract [sv]

Karlstads Energi AB äger fjärrvärmeverket på Heden som producerar både fjärrvärme och el till sina konsumenter. År 2001 producerade Karlstads Energi AB ca 540 GWh värme och ca 55 GWh el. För fjärrvärmeproduktionen används bland annat en flispanna och en avfallspanna som ligger vid Heden. Dessutom används en värmepump som ligger på Sjöstad vid reningsverket i Karlstad. Karlstads Energi AB kom med en förfrågan om förslag på förbättringar vid värmepumpen, framförallt efterfrågades hjälp med att utforma en ny regleranordning, för att förbättra regleringen av fjärrvärmevattnet in mot värmepumpen. Uppgiften har bestått av att med genomräkningar av värmepumpsprocessens huvudkomponenter titta efter möjligheter till effektivisering av värmepumpen, och att arbeta fram förslag på regleringsalternativ för ett optimalt flöde in till värmepumpen. Målsättningen har varit att med hjälp av beräkningar se om något kunde effektiviseras på värmepumpen och att ta fram tre genomtänkta förslag på regleranordningar som kan spara energi åt Karlstads Energi AB. Arbetsgången har varit att först titta på möjligheter till effektivisering av själva värmepumpsprocessen genom beräkningar på huvudkomponenterna. Därefter undersöktes rundpumpningens konsekvenser. Detta gjordes genom körning av värmepumpen (både med och utan rundpumpning) och en laboration vid Karlstads universitet. Slutligen arbetades tre alternativ på reglerfunktioner fram. Dessa genomfördes med genomgång av den reglerfunktion som finns idag och med tanke på rundpumpningens konsekvenser. Dessa tre alternativ är av olika reglertyper, de baseras på flödesreglering och temperaturreglering. Rundpumpning visade sig leda till att COP för anläggningen blev sämre. Orsaken var att temperaturen i kondensorn steg vid rundpumpning. Den ökade temperaturen ledde till att kompressorerna behövde göra en större tryckuppsättning, som i sin tur gav en större elförbrukning för kompressorerna. Resultatet av genomräkningen av huvudkomponenterna på värmepumpen visade att den fungerar bra. En flödesreglering med flödesgivare visade sig vara det bästa alternativet därför att man med flödesgivare kan eliminera rundpumpning.

Abstract [en]

Karlstads Energi AB owns the district heating plant at Heden that is producing both district heating and electricity to there consumers. Karstads Energi AB produced 2001 approximately 540 GWh heat and approximately 55 GWh electricity. For district heating production they use among others a woodchip boiler and a garbage boiler located at Heden. Further more a heat pump that is located at the sewage-treatment plant at Sjöstad is used. Karlstads Energi AB made an inquiry for a proposal of improvements of the heat pump; they especially wanted help to design a new function to improve the regulation of the water flow of district heating into the heat pump. The task consisted of calculations of the heat pump process to investigate possibilities to make the heat pump more efficient, and to produce alternatives of regulation of the district heating water flow in order to obtain a maximal flow into the heat pump. The objectives with the task was to with aid of calculations analyze if there exists possibilities to make the heat pump more efficient and to produce three alternatives for regulation of the district heating water flow that can save energy to Karlstads Energi AB. The work flow has been to first look into possibilities to make the heat pump process more efficient through calculations of the main components. After that the consequences of circular pumping was examined. This was made with help of an excel program, driving the heat pump (with and without circular pumping) and a laboration at Karlstads university. Finally three alternatives of regulations were produced. These were carried out with reviews of the regulation that is today and with regard to the consequences of circular pumping. These three alternatives are different types of regulations; they are based on flow and temperature regulation. Circular pumping showed that the COP of the heat pump becomes poorer. The reason to this was that the temperature rose in the condenser with circular pumping. The increased temperature caused the compressor to make a bigger pressure work, which increased the electric power consumption of the compressors. The result of the calculations of the main components on the heat pump showed that it works fine. A flow regulation with flow meter turned out to be the best alternative, due to the elimination of circular pumping.

Place, publisher, year, edition, pages
2002. , p. 40
Identifiers
URN: urn:nbn:se:kau:diva-54394Local ID: EMI-5OAI: oai:DiVA.org:kau-54394DiVA, id: diva2:1103109
Subject / course
Energy and Environmental Engineering, Bachelor of Science
Available from: 2017-05-30 Created: 2017-05-30

Open Access in DiVA

No full text in DiVA

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 246 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • apa.csl
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf