Fjärrvärmeutbyggnad
1999 (Swedish)Independent thesis Basic level (professional degree)Student thesis
Abstract [sv]

Institutionen för ingenjörsvetenskap, fysik och matematik Peter Lundell Dan Wingskog FJÄRRVÄRMEUTBYGGNAD District heating expansion Examensarbete vid Energi- och installationsprogrammet Juni 1999. Rapporten handlar om fjärrvärmeutbyggnad av området Högåsen och Myråsen i Arvika. En förstudie med avseende på kulvertdimensioner, dragningsväg och läggningsförfarande kommer att behandlas. Förslag ges på hur mejeriet i Arvika, Milko kan konverteras till fjärrvärme d v s vilken anslutningseffekt krävs för fjärrvärme. Arvika Fjärrvärmes anläggning analyseras, med avseende på verkningsgrader för varmvattenproduktionen och för det totala värmesystemet. Rapporten förklarar även hur ett fjärrvärmesystem fungerar samt dess ingående komponenter, mer om detta i bilaga 18. Vidare ges information om Arvika Fjärrvärme och deras anläggning. Olika metoder för läggning av kulvertrör, definition av verkningsgrader samt hur man dimensionerar ett kulvertsystem kommer också att redovisas. Hela Arvika Fjärrvärmes värmesystem har verkningsgraden, *system är lika med 82 %. Verkningsgraden för produktion av hetvatten *hv prd. är 90 % och förlusterna i kulvertar är 7 %. Effektbehovet på Milko består av produktion av ånga, uppvärmning av radiatorer, ventilationsluft, tappvarmvatten och förvärmning av matarvattentank (MAVA). Resultaten redovisas i tabell 1 nedan. Tabell 1. Effektförbrukning Milko FÖRBRUKARE PÅ MILKO EFFEKT [ kW] RADIATORKRETS 217 TAPPVARMVATTEN 335 FÖRVÄRMNING MAVA-TANK 116 VENTILATION 377 ANSLUTNINGSEFFEKT 1045 Förstudien bygger på att alla hus intill den preliminära kulvertdragningen på sikt kommer att ansluta sig. Kulvertdimensionerna som krävs är DN150 från Fältgatan till Dungen. En DN125 från Dungen fram till korsningen Myråsvägen/Gästgivarevägen. Från denna korsning fram till Milko krävs DN100. Dimensionerna på de avstick som gjorts redovisas i Bilaga 3. Förslag på hur kulverten i ovanstående område kan läggas grundar sig på markens beskaffenhet samt eventuella hinder i dragningsvägen. Den bästa läggningsmetoden längs aktuella gator är rörgrav (Bild 5, bil.19). Kedjegrävning alt. rörgrav beroende på markbeskaffenhet, är den lämpligaste metoden för servisdragning. Över grönområdet mellan Mejerigatan och Högåsvägen är plöjning att föredra. Under Högåsvägen fram till Milkos område kan rörramning användas. Val och motiveringar av läggningsmetoder presenteras vidare under kap 10. -- This is a graduation report containing the aspects of district heating expansion in Högåsen, Arvika. The principal is Arvika Fjärrvärme AB. The report contains three main questions, which are: - Solve the convertion from own created energy to district heating connection for the dairy Milko in Arvika. - Calculate the rate of efficiency for the hot water generation (*hw.prd) - and for the total district heating system (*system). - Investigation of a district heating expansion of the region Högåsen in the city of Arvika. The report also explains how the total district heating system works (Encl. 18). Information about Arvika Fjärrvärme and their establishment are also mentioned. Different methods of plumbing, definition of efficiency rate, pipe-dimensioning in a district heating net will also be described. The district heating system has the rate of efficiency *system = 82 %. The boilers performance of making hot water *hw.prd = 90 % and the total loss of heat energy in pipes and exchangers are 8%. The need of effect in Milko consists of steam generation, radiators, ventilation system, manufacturing of hotwater, and preheating of a storagetank to the steamboiler at Milko. All these effects lead to a total need for Milko which the district heating must provide. The results are shown in table 1. Tabel 1. Effect at Milko CONSUMERS AT MILKO EFFECT [ kW] RADIATORES 217 HOT WATER 335 PRE HEATING OF STORAGE TANK 116 VENTILATION 377 EFFECT OF CONNECTION 1045. The first issue about expansion, presupose that all the buildings in that particular area of expansion will connect to district heating. The dimensions of the pipes will be DN150 from the street Fältgatan to the housing Dungen. From Dungen to the street Mejerigatan is DN125 needed. The last distance from Mejerigatan to the dairy Milko, demands DN100. These tree pipes make the mainpipe and from this mainpipe there are some detoures leading in to minor areas of the Högåsen region. These detoures are shown in enclosure 3. The choice of plumbing methods are related to the ground constitution and eventual obstacles in the planned way of plumbing. The best and most common plumbingmethods is to dig a pipeshaft (See pic. 5, encl. 19). A small tractor with a special excavationdevice or create a minor pipeshaft is common ways of plumbing housedetoures. Choices of plumbing methods are shown in chapter 5,5.

Place, publisher, year, edition, pages
1999. , 57 p.
Identifiers
URN: urn:nbn:se:kau:diva-54334Local ID: ENI-4OAI: oai:DiVA.org:kau-54334DiVA: diva2:1103049
Subject / course
Energy and Environmental Engineering, Bachelor of Science
Available from: 2017-05-30 Created: 2017-05-30

Open Access in DiVA

No full text

Search outside of DiVA

GoogleGoogle Scholar

Total: 6 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf