Fuktproblem vid tilläggsisolering
2005 (Swedish)Independent thesis Basic level (professional degree)Student thesis
Abstract [sv]

Vid tilläggsisolering av vindar uppstår ofta fuktproblem i vindsutrymmet. Detta beror på att vinden blir kallare varpå den också blir fuktigare. Ett sätt att minska risken för fuktskador på vinden är att öka ventilationen inomhus, och på så vis minska fuktflödet upp till vinden. Rapporten behandlar besparing för tilläggsisolering av villor belägna i Karlstad byggda mellan 50-talet och 80-talet. I samtliga beräknade fall behövdes ventilationen inne ökas för att fuktförhållandet på vinden inte skulle bli sämre än innan tilläggsisoleringen. I beräkningen av pay-off-tiden har hänsyn tagits till den förlust som blir genom ökad ventilation inne, i samband med tilläggsisoleringen. De hus som är mest lönsamma att tilläggsisolera är hus byggda under 50- och 60-talet. Vid villor byggda under 70-talet är isoleringsmängden samt ventilationen före tilläggsisoleringen avgörande för om det blir lönsamt med tilläggsisolering. I hus byggda under 80-talet är det däremot inte lönsamt att tilläggsisolera, då de oftast är kraftigt isolerade från början. Ventilationen inne är en viktig faktor för fuktklimatet på vinden, speciellt vid hög fuktproduktion samt otätt vindsbjälklag. Det är därför viktigt att kontrollera att ventilationen inne är tillräcklig, samt att tätheten i vindsbjälklaget undersöks innan tilläggsisolering utförs.

Abstract [en]

When implementing additional insulation of attics, humidity damages often occurs. The insulation causes a drop in temperature and the air of the attic becomes humid. One way to decrease the risk for moisture related damages on attics is to increase the ventilation indoors, and that way diminish the humidity flow to the attic. The report describes additional insulation savings of houses built between 1950 and 1980 in Karlstad. To not worsen the humidity condition on the attics prior to the additional insulation, in all instances, the indoor ventilation needed to be increased. The loss anticipated by the increased indoor ventilation in conjunction with additional insulation has been taken into consideration when estimating the pay-off time. Houses built in the 1950’s and 1960’s are most profitable to add additional insulation to. For houses built in the 70’s, the thickness of the insulation along with indoor ventilation prior to the adding of insulation are crucial elements to consider when estimating if additional insulation is profitable. However, houses built in the 80’s it is usually not profitable to add extra insulation since they generally are heavy insulated originally. The indoor ventilation is an important factor for the humidity condition on the attic, especially when the attic joist floor is loose and at high-level moist production. It is therefore important to check that the indoor ventilation is sufficient and that the tightness of the attic joist floor is examined before additional insulation is implemented.

Place, publisher, year, edition, pages
2005. , p. 44
Identifiers
URN: urn:nbn:se:kau:diva-49185Local ID: BYI-8OAI: oai:DiVA.org:kau-49185DiVA, id: diva2:1097581
Subject / course
Building Engineering, Bachelor of Science
Available from: 2017-05-22 Created: 2017-05-22

Open Access in DiVA

No full text in DiVA

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 175 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • apa.csl
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf