Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • apa.csl
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Out-of-Plane Visual Servoing Method for Tracking the Carotid Artery with a Robot-Assisted Ultrasound Diagnostic System
Japan.
Japan.ORCID-id: 0000-0002-6865-7346
Japan.
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: 2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), IEEE conference proceedings, 2011Konferensbidrag, Publicerat paper (Refereegranskat)
Resurstyp
Text
Abstract [en]

Up to now, there are different kinds of robot-assisted ultrasound diagnostic systems proposed in the last decade. However, the compensation of the ultrasound probe position according to the patient movement is still one of the most important and useful functions required for those systems. For this purpose, in this research, we aim at developing an automated diagnostic system for the measurement of the wave intensity which is usually measured at the common carotid artery. In particular, in this paper, we focus on proposing a robust visual servoing method for tracking out-of-plane motion for a robot-assisted medical ultrasound diagnostic system by using a conventional 2D probe. A robotic device which manipulates the ultrasound probe firstly scans a small area around the target position and records several B-mode images at a regular interval. In order to track the out-of-plane motion, an inter-frame block matching method has been proposed and implemented on the Waseda-Tokyo Women's Medical-Aloka Blood Flow Measurement System No. 2 Refined (WTA-2R). A set of experiments was proposed to verify the effectiveness of the proposed method. From the experimental results, we could confirm its robustness while doing the task with real human tissues.

Ort, förlag, år, upplaga, sidor
IEEE conference proceedings, 2011.
Serie
IEEE International Conference on Robotics and Automation ICRA, ISSN 1050-4729
Nyckelord [en]
:FREEHAND 3-D ULTRASOUND; INTENSITY
Nationell ämneskategori
Robotteknik och automation
Forskningsämne
Fysik
Identifikatorer
URN: urn:nbn:se:kau:diva-44673ISI: 000324383404079ISBN: 978-1-61284-385-8 (tryckt)OAI: oai:DiVA.org:kau-44673DiVA, id: diva2:952217
Konferens
IEEE International Conference on Robotics and Automation (ICRA), MAY 09-13, 2011, Shanghai, PEOPLES R CHINA
Tillgänglig från: 2016-08-12 Skapad: 2016-08-12 Senast uppdaterad: 2017-12-06Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Person

Solis, Jorge

Sök vidare i DiVA

Av författaren/redaktören
Solis, Jorge
Robotteknik och automation

Sök vidare utanför DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 203 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • apa.csl
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf