Study of using a capillary tube in a heat pump dishwasher with transient heating
ASKO Appliances AB, Sockerbruksgatan 3, SE-53140 Lidkoping, Sweden.ORCID-id: 0000-0002-5101-3800
Karlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013), Institutionen för ingenjörs- och kemivetenskaper (from 2013).ORCID-id: 0000-0002-9707-8896
2016 (engelsk)Inngår i: International journal of refrigeration, ISSN 0140-7007, E-ISSN 1879-2081, Vol. 67, s. 1-9Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

For competitive purposes, manufacturers of household appliances need to produce appliances that use less electricity. One way of doing this for a dishwasher is to add a heat pump system. Previous studies using R134a as refrigerant have shown that the addition of a heat pump can reduce total electricity consumption by about 24%. This paper reports on the use of a capillary tube in a heat pump dishwasher during the transient heating period. Working with an available compressor, the mass of R600a and the length of a 0.9 mm capillary tube were varied in order to find the configuration with the lowest electricity consumption. Three methods of calculating the length of the capillary tube were used to determine five lengths for evaluation. The results show that using a single capillary tube throughout the transient heating period yields similar electricity consumption to a variable expansion device which occurred by switching the capillary tube between two or three different lengths during the heating period.

sted, utgiver, år, opplag, sider
Elsevier, 2016. Vol. 67, s. 1-9
Emneord [en]
Home appliances, Expansion device, Environmental impact, Natural refrigerant, Energy use
HSV kategori
Forskningsprogram
Energiteknik
Identifikatorer
URN: urn:nbn:se:kau:diva-44653DOI: 10.1016/j.ijrefrig.2016.04.006ISI: 000378951900002OAI: oai:DiVA.org:kau-44653DiVA, id: diva2:952142
Tilgjengelig fra: 2016-08-11 Laget: 2016-08-11 Sist oppdatert: 2019-10-21bibliografisk kontrollert
Inngår i avhandling
1. Apply heat pump systems in commercial household products to reduce environmental impact: How to halve the electricity consumption for a household dishwasher
Åpne denne publikasjonen i ny fane eller vindu >>Apply heat pump systems in commercial household products to reduce environmental impact: How to halve the electricity consumption for a household dishwasher
2017 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

In the household appliance industry, heat pump systems have been used for a long time in refrigerators and freezers to cool food, and the industry has driven the development of small, high-quality, low-price heat pump components. In the last few decades, heat pump systems have been introduced in other household appliances, with the express purpose of reducing electricity consumption. Heat pump tumble dryers have been on the market since 2000 and dominate the market today. A heat pump dishwasher was introduced on the market in 2014 and a heat pump washing machine in 2016. The purpose of adding a heat pump system in these three products was to decrease electricity consumption.

Papers I and II used a methodology where transient simulation models were developed and used to increase knowledge about how to decrease electricity consumption for a tumble dryer and a dishwasher by adding a heat pump system. Papers II to V showed that a lower electricity consumption and lower global warming potential together with an energy-efficient drying method, where no humid air evacuates to the kitchen, give a heat pump dishwasher competitive advantages compared to any conventional dishwasher currently on the market. Using simulations, this dissertation concludes that a future commercial heat pump dishwasher, using R600a as a refrigerant, will reduce electricity consumption and total equivalent warming impact (TEWI) by 50% compared to the conventional dishwasher.

The willingness from the customer chain to pay extra for this heat pump dishwasher is because of the decreases electricity consumption and the fact that no humid air evacuates to the kitchen. This willingness makes the heat pump dishwasher to a variant which have possibility to succeed on the future market.

The challenge for the manufacturer is to develop and produce a high-quality heat pump dishwasher with low electricity consumption, predict future willingness to pay for it, and launch it on the market at the right moment with the right promotion in order to succeed.

Abstract [en]

The competition in the household appliances industry is strong. Manufacturers are continuously trying to develop, produce and sell product functions and features with good profit. To continually develop new features that the customer chain is willing to pay for is a key factor for a manufacturer to survive.

In this study has a heat pump system been added as a new feature to a dishwasher. The first heat pump dishwasher was introduced on the market in 2014 and the heat pump system was only used to heat the dishwasher. Comparing that first heat pump dishwasher was a new closed drying method introduced in this study where no humid air evacuates to the kitchen. Experiments and simulations showed that a dishwasher with an added heat pump system can decrease the total electricity consumption by 50% when cleaning and drying the dishware comparing to an on market conventional dishwasher.

The willingness from the customer chain to pay extra for this heat pump dishwasher is because of the decreases in electricity consumption and the fact that no humid air evacuates to the kitchen. This willingness makes the heat pump dishwasher to a variant which have possibility to succeed on the future market.

sted, utgiver, år, opplag, sider
Karlstads universitet, 2017
Serie
Karlstad University Studies, ISSN 1403-8099 ; 2017:10
Emneord
household appliance, electricity consumption, heat pump, environmental impact
HSV kategori
Forskningsprogram
Miljö- och energisystem
Identifikatorer
urn:nbn:se:kau:diva-48132 (URN)978-91-7063-759-9 (ISBN)978-91-7063-760-5 (ISBN)
Disputas
2017-05-05, 9C203, Nyquistsalen, Karlstad, 09:15 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2017-04-13 Laget: 2017-03-13 Sist oppdatert: 2019-10-21bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Bengtsson, PederBerghel, Jonas

Søk i DiVA

Av forfatter/redaktør
Bengtsson, PederBerghel, Jonas
Av organisasjonen
I samme tidsskrift
International journal of refrigeration

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 257 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf