Satisfactory reliability among nursing students using the instrument PVC ASSESS to evaluate management of peripheral venous catheters
Karolinska Inst, Dept Clin Sci, Div Surg, Stockholm, Sweden..
Karolinska Inst, Dept Clin Sci, Div Surg, Stockholm, Sweden..
Karlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013), Institutionen för hälsovetenskaper.
Karolinska Inst, Care Sci & Soc, Div Nursing, Dept Neurobiol, Stockholm, Sweden..
Vise andre og tillknytning
2014 (engelsk)Inngår i: Journal of Vascular Access, ISSN 1129-7298, E-ISSN 1724-6032, Vol. 15, nr 2, s. 128-134Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

Purpose: Nursing students should be given opportunities to participate in clinical audits during their education. However, audit tools are seldom tested for reliability among nursing students. The aim of this study was to present reliability among nursing students using the instrument PVC assess to assess management of peripheral venous catheters (PVCs) and PVC-related signs of thrombophlebitis. Methods: PVC assess was used to assess 67 inserted PVCs in 60 patients at ten wards at a university hospital. One group of nursing students (n= 4) assessed PVCs at the bedside (inter-rater reliability) and photographs of these PVCs were taken. Another group of students (n= 3) assessed the PVCs in the photographs after 4 weeks (test-retest reliability). To determine reliability, proportion of agreement [P(A)] and Cohen's kappa coefficient (k) were calculated. Results: For bedside assessment of PVCs, P(A) ranged from good to excellent (0.80-1.0) in 55% of the 26 PVC assess items that were tested. P(A) was poor (< 0.70) for two items: "adherence of inner dressing to the skin" and " PVC location." In 81% of the items, k was between moderate and almost perfect: moderate (n= 5), substantial (n= 3), almost perfect (n= 5). For edema at insertion site and two items on PVC dressing, k was fair (0.21-0.40). Regarding test-retest reliability, P(A) varied between good and excellent (0.81-1) in 85%-95% of the items, and the k ranged between moderate and almost perfect (0.41-1) in 90%-95%. Conclusions: PVC assess demonstrated satisfactory reliability among nursing students. However, students need training in how to use the instrument before assessing PVCs.

sted, utgiver, år, opplag, sider
2014. Vol. 15, nr 2, s. 128-134
Emneord [en]
Assessment, Inter-rater reliability, Nursing student, Peripheral venous catheter, test-retest reliability
HSV kategori
Identifikatorer
URN: urn:nbn:se:kau:diva-41546DOI: 10.5301/jva.5000192ISI: 000339997000010PubMedID: 24170582OAI: oai:DiVA.org:kau-41546DiVA, id: diva2:923109
Tilgjengelig fra: 2016-04-25 Laget: 2016-04-11 Sist oppdatert: 2017-11-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Nordström, Gun

Søk i DiVA

Av forfatter/redaktør
Nordström, Gun
Av organisasjonen
I samme tidsskrift
Journal of Vascular Access

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 219 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf