Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Estimated Droop Control for Parallel Connected Voltage Source Inverters: Stability Enhancement
Karlstads universitet, Fakulteten för teknik- och naturvetenskap, Avdelningen för fysik och elektroteknik.
2013 (Engelska)Självständigt arbete på avancerad nivå (magisterexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Renewable Energy Sources (RES) are considered as the replacement of conventionalenergy sources. These RES can use wind energy, solar light, bio waste and can alsobe in the form of small hydro power units. These RES has very poor power qualityand contains voltage uctuations and variable frequency. These factors make RES astability risk for the main utility grid. As a solution, currently inverters with dierentdesign techniques are being used as an interface between RES and main utility grid. Thecurrent study proposed a new technique "estimated droop control" for inverter design.The conventional droop control technique which was already used in inverter design, hasdiculty in synchronizing parallel connected inverters with dierent droop gains and lineimpedances. The proposed "estimated droop control" does not use any predened droopvalues for inverters and all inverters are responsible for the estimation of their own droopvalues with respect to their output power. Therefore, inverters are not bound to usesame and static droop values which are considered as a vital communication link. Theproposed design methodology has made inverters independent from this only virtual linkof communication due to which the reliability of a system has increased. The proposeddesign technique has given very good results in a simulation run. When the Simulinkmodel was run in parallel connected inverter with dierent line impedances, it was asuccess as both inverters started operating with same droop values as they were sharingan equal load. The most important test was with dierent line impedances because inconventional droop control it is dicult for inverters to keep their synchronism withdierent line impedances and an unequal load sharing make inverters to deviate fromtheir nominal values and to generate dierent tracking signals for each set. This problemhas been successfully solved with estimated droop control as in this method each inverterset its droop gains according to its output power, which helps an inverter to operate atnominal values with dierent droop gains and line impedance.

Ort, förlag, år, upplaga, sidor
2013. , s. 100
Nationell ämneskategori
Reglerteknik
Identifikatorer
URN: urn:nbn:se:kau:diva-30794OAI: oai:DiVA.org:kau-30794DiVA, id: diva2:682929
Externt samarbete
Fraunhofer IWES, Kassel Germany
Ämne / kurs
Elektroteknik
Presentation
2013-11-29, 21D302, Karlstad University, Universitetsgatan 2, Karlstad, 16:30 (Engelska)
Handledare
Examinatorer
Tillgänglig från: 2014-01-07 Skapad: 2013-12-30 Senast uppdaterad: 2014-01-07Bibliografiskt granskad

Open Access i DiVA

Faisal(8699 kB)1678 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 8699 kBChecksumma SHA-512
91feff99d812befccefee7f1071bf0a07203608dac051fce063719c525780942464d56d322c84528d475948428a55e905eb4260b826debd41468e015574b13d1
Typ fulltextMimetyp application/pdf
Arkivfil(8562 kB)896 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 8562 kBChecksumma SHA-512
40315d4815657610ada5502464ab8f39e634780638ff74d730b65ead0c345ce9c398904bc21e585013be8ef45426396b499cb11e3172f4af7befaae3757e787b
Typ fulltextMimetyp application/pdf

Av organisationen
Avdelningen för fysik och elektroteknik
Reglerteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 2574 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 1668 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf