Microextraction in Packed Syringe Online with Liquid Chromatography-Tandem Mass Spectrometry: Molecularly imprinted polymer as packing material for MEPS in selective extraction of ropivacaine from plasma
AstraZeneca R&D Södertälje, Södertälje, Sweden.
AstraZeneca R&D Södertälje, Södertälje, Sweden.
Karlstad University, Faculty of Technology and Science, Department of Chemistry and Biomedical Sciences.
Karlstad University, Faculty of Technology and Science, Department of Chemistry and Biomedical Sciences.
2006 (English)In: Journal of Liquid Chromatography & Related Technologies, ISSN 1082-6076, E-ISSN 1520-572X, Vol. 29, no 12, p. 1725-1736Article in journal (Refereed) Published
Abstract [en]

The excellent performance of a new sample preparation method, microextraction in packed syringe (MEPS), was recently illustrated by online LC‐MS and GS‐MS assays of local anaesthetics in plasma samples. In the method, approximately 1 mg of solid packing material was inserted into a syringe (100–250 µL) as a plug. Sample preparation took place on the packed bed. The new method was easy to use, fully automated, of low cost, and rapid in comparison with previously used methods. This paper presents the use of molecularly imprinted polymers (MIPs) as packing material for higher extraction selectivity. Development and validation of a method for MIP‐MEPS online with LC‐MS‐MS using ropivacaine in plasma as model compound were investigated. A bupivacaine imprinted polymer was used. The method was validated and the standard curves were evaluated by means of quadratic regression and weighted by inverse of the concentration: 1/x for the calibration range 2–2000 nM. The applied polymer could be used more than 100 times before the syringe was discarded. The extraction recovery was 60%. The results showed high correlation coefficients (R 2 >0.999) for all runs. The accuracy, given as a percentage deviation from the nominal concentration values, ranged from -6% to 3%. The precision, given as the relative standard deviation, at three different concentrations (QC samples) was consistently about 3% to 10%. The limit of quantification was 2 nM.

Place, publisher, year, edition, pages
2006. Vol. 29, no 12, p. 1725-1736
Keywords [en]
Column liquid chromatography‐tandem mass spectrometry, Column liquid chromatography-tandem mass spectrometry, Molecularly imprinted polymers, Ropivacaine, Sample preparation
National Category
Chemical Sciences
Research subject
Chemistry
Identifiers
URN: urn:nbn:se:kau:diva-21457DOI: 10.1080/10826070600716843OAI: oai:DiVA.org:kau-21457DiVA, id: diva2:595131
Available from: 2013-01-21 Created: 2013-01-21 Last updated: 2017-12-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Altun, ZekiBlomberg, Lars G

Search in DiVA

By author/editor
Altun, ZekiBlomberg, Lars G
By organisation
Department of Chemistry and Biomedical Sciences
In the same journal
Journal of Liquid Chromatography & Related Technologies
Chemical Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 505 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • apa.csl
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf