Energianalys vid sprängmedelsfabriken Orica Sweden AB: Möjligheter att minska energibehovet i byggnad 2100 och 2100A
Karlstad University, Faculty of Technology and Science, Department of Energy, Environmental and Building Technology.
2012 (Swedish)Independent thesis Basic level (university diploma), 15 credits / 22,5 HE creditsStudent thesisAlternative title
Energy analysis at explosives factory Orica Sweden AB : Opportunities to reduce energy demand in building 2100 and 2100A (English)
Abstract [sv]

Att minska energibehovet för en byggnad är ett sätt att nå riksdagens mål att minska energianvändandet med 20 % till år 2020. Vilket också leder till minskade utsläpp av växthusgaser och är ett led till hållbar utveckling. Orica Sweden AB i Gyttorp tillverkar, sprängämne, förstadium till sprängämne samt tändmedel till den civila marknaden. Orica Sweden AB har genom en energikartläggning utförd av Sweco funnit att deras energianvändning kan minska. Detta framför allt i den östra delen av industriområdet. Där finns byggnaden 2100 med tillbyggnaden 2100 A.

I detta arbete studeras möjligheter för att minska energibehovet i byggnaderna 2100 och 2100A på Orica Sweden AB i Gyttorp. Det innebär i första läget att analysera energibehovet idag och sedan utvärdera åtgärdsförslag för minskad energianvändning.

Följande åtgärdsförslag har studerats:

  • En sänkning av temperaturen på tilluften i ventilationen
  • Anpassning av ventilationens drifttid
  • Inkoppling av befintlig utrustning för värmeåtervinning
  • Investering av nya ventilationsaggregat med högre temperaturverkningsgrad på återvinningssystemet och evaporativ kylning där så är möjligt
  • En teknisk lösning för att återvinna värme från kondensorn på en kylmaskin
  • En teknisk lösning för att återvinna värme från två tryckluftskompressorer

Detaljmätningar och beräkningar ligger till grund för åtgärdsförslagen. Mätningarna av luftflöden i ventilationen utfördes med varmtrådsanemometer. Volymflödet i kondensorledningen uppmättes med flödesmätare och för mätning av strömförbrukning loggades strömmen med en amperemätare. Det totala energibehovet för uppvärmning, befuktning, kylning och avfuktning av ventilationsluften för samtliga sex ventilationsaggregaten i 2100 och ett aggregat i 2100A uppkom till sammanlagt 2118 MWh/år. Med införda åtgärder i form av ovanstående kan energibehovet totalt minska till 1057 MWh/år vilket motsvarar 50 % av det beräknade energibehovet idag.

 

Abstract [en]

Reducing the energy of a building is a way to reach the parliament aims to reduce energy use by 20% by 2020. This will also result in reduced emissions of greenhouse gases which is part of sustainable development. Orica Sweden AB in Gyttorp manufactures explosives and igniters to the civilian market. A survey on the energy usage performed by Sweco concludes that energy savings can be made, especially in the buildings located on the eastern parts of Oricas industrial area. This is where the buildings 2100, with the extension 2100A are situated.

This study focuses on opportunities to reduce energy demand in buildings 2100 and 2100A at Orica Sweden AB in Gyttorp. The energy demand today is analyzed, and several proposed measures to reduce energy use are evaluated. The following measures are investigated:

  • A reduction in the supply air temperature in ventilation
  • Adapting runtime for ventilation
  • Connection of existing equipment for heat recovery
  • Investment of new air handling units with higher heat recovery efficiency of the recycling system and evaporative cooling where possible
  • A technical solution for heat recovery from the condenser of a chiller
  • A technical solution for heat recovery from two air compressors

Detailed measurements and calculations underlying the suggestions result. Measurements of air flow in ducts were performed by hot wire thermometer. The volume flow of the condenser where measured by flowmeters and measurement of current was logged by an ampermeter. The total energy demand for heating, humidification, cooling and dehumidification of ventilation air for all handling units is calculated 2118 MWh / year. The measures introduced can reduce the energy demand to 1057 MWh /year, which represents 50% of the estimated energy needs today.

 

 

 

 

 

Place, publisher, year, edition, pages
2012. , p. 51
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:kau:diva-16187Local ID: EMI-15OAI: oai:DiVA.org:kau-16187DiVA, id: diva2:577811
External cooperation
Sweco
Subject / course
Energy and Environmental Engineering, Bachelor of Science
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-12-18 Created: 2012-12-17 Last updated: 2012-12-18Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Department of Energy, Environmental and Building Technology
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 438 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • apa.csl
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf