Analysis of switching effects of vacuum circuit breaker on dry-type foil-winding transformers validated by experiments
Delft Univ Technol, Fac EEMCS, NL-2628 CD Delft, Netherlands..ORCID-id: 0000-0001-9750-9863
Delft Univ Technol, Fac EEMCS, NL-2628 CD Delft, Netherlands..
Siemens AG, Power Transmiss Div Transformers, D-73230 Kirchheim Unter Teck, German.
Siemens AG, Power Transmiss Div Transformers, D-90461 Nurnberg, Germany.
Visa övriga samt affilieringar
2015 (Engelska)Ingår i: IEEE Transactions on Power Delivery, ISSN 0885-8977, E-ISSN 1937-4208, Vol. 30, nr 1, s. 351-359Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this paper, the prestrike and the restrike effects during switching a vacuum circuit breaker (VCB) connected to a dry-type foil-winding transformer are theoretically and experimentally analyzed. The analysis is conducted by performing a wide range of experimental three-phase switching ON/OFF tests for a 3.75-MVA prototype test transformer connected to a VCB by a cable with different lengths and for different loading conditions. A refined transformer model is successfully applied for the computation of the voltage distribution along the transformer windings. In particular, the winding properties are separately investigated, for which the core influence for frequencies above some tens of kilohertz is studied, and the terminal impedance variation for a broad frequency range is accurately calculated. The simulated results are excellent. Based on these results, an analysis was performed to evaluate the severity of the switching operations by applying spectral analysis of the recorded signals. The statistical analysis of the overvoltages with respect to the cable length and the load value shows that long cables do not guarantee lower overvoltages because of the load and its interaction with the system that makes each case unique. © 2014 IEEE.

Ort, förlag, år, upplaga, sidor
IEEE, 2015. Vol. 30, nr 1, s. 351-359
Nyckelord [en]
Cables; Electric transformer testing; Models; Resonance; Spectrum analysis; Switching; Transformer windings; Transients; Winding, Broad frequency range; Over-voltages; Severity factor; Switching operations; Transformer; Transformer modeling; Vacuum circuit breaker; Voltage distribution, Electric circuit breakers
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:kau:diva-63766DOI: 10.1109/TPWRD.2014.2327073ISI: 000348375100040Scopus ID: 2-s2.0-85027955909OAI: oai:DiVA.org:kau-63766DiVA, id: diva2:1142067
Tillgänglig från: 2017-09-18 Skapad: 2017-09-18 Senast uppdaterad: 2019-05-27Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Theocharis, Andreas

Sök vidare i DiVA

Av författaren/redaktören
Theocharis, Andreas
I samma tidskrift
IEEE Transactions on Power Delivery
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 202 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf